Compositional Analysis of the High Molecular Weight Ethylene Oxide-Propylene-Oxide Copolymer by MALDI Mass Spectrometry


  •  Orwa Housheya    
  •  Charles Wilkins    

Abstract

The composition of narrow distribution poly ethylene oxide-propylene oxide copolymer (Mw ~ 8700 Da) was studied using matrix assisted laser desorption ionization (MALDI) mass spectrometry. The ethylene oxide-propylene oxide copolymer produced oligomers separated by 14 Da. The average resolving power over the entire spectrum was 28,000. Approximately 448 isotopically resolved peaks representing about 56 oligomers are identified. Although agreement between experimental and calculated isotopic distributions was strong, the compositional assignment was difficult. This is due to the large number of possible isobaric components. The purpose of this research is resolve and study the composition of high mass copolymer such as ethylene oxide-propylene oxide.



This work is licensed under a Creative Commons Attribution 4.0 License.
  • ISSN(Print): 1916-9698
  • ISSN(Online): 1916-9701
  • Started: 2009
  • Frequency: semiannual

Journal Metrics

h-index (December 2022): 32

i10-index (December 2022): 145

h5-index (December 2022): N/A

h5-median(December 2022): N/A

( The data was calculated based on Google Scholar Citations. Click Here to Learn More. )

Contact